ZIPPY 1U REDUNTANT 120W PSU R1T2-5120V0H 215 X 106 X41.5 mm For Server
FEATURES
* TEMPERATURE RANGE:OPERATING 0℃~50℃, STORAGE -20℃~80℃
* HOLD UP TIME:WHEN POWER SHUTDOWN DC OUTPUT 12V MUST BE MAINTAIN 17MSEC IN REGULATION LIMIT AT NORMAL INPUT VOLTAGE
* THE MAXIMUM POWER SUPPLY SYSTEM EFFICIENCY SHALL BE 86%, MEASURED AT NOMINAL INPUT VOLTAGE 230 V AND FULL LOADING(+12V:10A).
* LEAKAGE CURRENT: 3.5 MA. MAX. AT NOMINAL VOLTAGE 250VAC
* REMOTE ON/OFF CONTROL
* POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS,OFF DELAY 1Ms
* OVER POWER PROTECTION:110~150% MAX
* OVER VOLTAGE PROTECTION: +5V→5.7~6.5V, +3.3V→3.7~4.1V, +12V→12.8~15V
* SHORT CIRCUIT PROTECTION: +5V, +3.3V, +12V, -12V, +5VSB
* SAFETY: MEET ULCUL, TUV, CCC
* WARNING METHOD: AUDIO ALARM(BUZZER SOUND, RESETABLE), FALUT LED, TTL
* THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.
OUTPUT WATTAGE
120W
BEST SOLUTION FOR
Server
DIMENSION
215x106x41.5(mm)
8.46×4.17×1.63(inch)
INPUT SPEC
VOLTAGE: 90~264VAC FULL RANGE
FREQUENCY: 47~63HZ
INPUT CURRENT:2A (RMS) FOR 115 VAC
1A (RMS) FOR 230 VAC
INRUSH CURRENT:35A MAX. FOR 115 VAC PER MODULE
70A MAX. FOR 230 VAC PER MODULE
DC OUTPUT SPEC
Output Voltage Output Current Min. Output Current Max. Regulation Load Regulation Line Output Ripple Noise Max.[P-P]
+5V 0 10 ±5% ±1% 50mV
+12V 2 10 ±5% ±1% 120mV
+3.3V 0 10 ± 5% ±1% 50mV
-12V 0 0.3 ±10% ± 1% 120mV
+5VSB 0.1 3 ±5% ±1% 50mV
Product Last Updated: 02/07/2024
Reviews
There are no reviews yet.